Router modules

1

Power supply requirements for BR-MLX-1GFx24-X and BR-MLX-1GFx24-X-ML interface modules

Table 18

lists the power supply requirements for each type of router when installing 24-port 1 Gbps

fiber interface modules.

20-port 100/1000 Ethernet interface module

Figure 23

shows the front panel of the 20-port 100/1000 Gbps Ethernet SFP interface module.

FIGURE 23

20-port 100/1000 Ethernet module front panel

TABLE 18

Power supply requirements for 24-port 1 Gbps fiber interface module

Router type

Number of 24-port 1
Gbps fiber interface
module installed

Power supply requirements

MLXe-4

three

one 1200W PSU
for 1+1 redundancy, install two 1200W PSU

four

two 1200W PSU
for 2+2 redundancy, install four 1200W PSU

MLX-4 and