JLG X17J Plus Operator Manual User Manual
Page 131

127
7.13 CHECKING THE HYDRAULIC OIL LEVEL
The check must be carried out with the platform (EWP) and the stabilisers in the resting
position on flat ground.
Check the oil level on indicator A; the oil must be half way up the level indicator.
If this is not the case, top up through cap B.
7.13.1 HYDRAULIC OIL
For top‑up or replacement of hydraulic oil ONLY use JLG oil.
7.14 CHECKING FOR LEAKS IN THE HYDRAULIC SYSTEM
Visually check all hoses, connections and all other components in the hydraulic system, in
order to identify any possible leaks.
Leaks from hoses can normally be resolved by tightening the fittings.
Leaks from gaskets (O rings, sealing rings etc.) cannot be eliminated by simply tightening, as
gaskets usually leak because they are damaged or have become hard.
The correct tightness can only be restored by replacing the gasket.
BOOM LIFT MODELS X17JPLUS
JLG
X17JPR0020413
A
B