6.5.2 OPERATING THE MACHINE FROM THE EMERGENCY CONTROL POSITION
ON THE GROUND IF THE OPERATOR IS TAKEN ILL

This function is only used if the operator in the basket becomes suddenly ill and unable to
perform ordinary movements and the emergency descent of the basket.

For information on the controls in the emergency position, see the paragraph

Emergency

position controls.

Withdraw the opening key of the distributor’s controls pro‑
tection from the engine keys group in the electrical compo‑
nents box.

Insert the key to open the distributor’s controls protection
and access the controls.

Operate on the enabling selector in the control panel of the
emergency position, rotating it clockwise and keeping it in
position (in the Lithium version this starts the engine).

Start the motor using the corresponding button in case of thermic version.

Rotate the key selector clockwise and hold it in position (in Lithium version this starts
the motor).

Make sure that the green indicator light on the emergency position control panel comes
on, i.e. that the conditions necessary to be able to move the aerial part are satisfied.

Move the aerial part of the machine using the manual levers positioned on the distri‑
butor on the ground as described on the sticker placed near them and as specified in
this manual.

Close the protection and put the keys back in their original position.

The sole purpose of the emergency descent from the ground is to operate in the event of
system breakdown and to bring the basket to the ground, all other uses are prohibited.

X17JPR0020413

BOOM LIFT MODELS X17JPLUS

JLG

93

THERMIC MOTOR

LITHIUM MOTOR

Advertising