3.5 STABILISER POSITION MICROSWITCHES, STANDARD VERSION
The position of the stabilisers and their contact with the ground are detected by 4 microswit‑
ches positioned near the stabiliser cylinder rod fastening pin. The microswitches fixed to the
stabiliser must be released when the stabiliser rests on the ground.
Check the correct operation of the microswitches every day.
3.6 JIB POSITION MICROSWITCH
The position of the jib arm is detected by a microswitch that is secured to the jib arm itself.
The microswitch must be released when the jib arm is closed.
Check the condition and correct operation of the JIB microswitch every day.