JLG X17J Plus Operator Manual User Manual

Page 160

Advertising
background image

ALARMS

INVERTER FAULT CODES

X17JPR0020413

156

BOOM LIFT MODELS X17JPLUS

JLG

CODE

MEANING

1

Wrong Config
Cause: EEPROM memory not configured.
Solution: Contact after‑sales service.

8

Watch Dog
Cause: Inverter cannot start or stop electric motor.
Solution: Check connections and continuity of electric motor. If OK, replace
inverter.

13

Eeprom KO
Cause: EEPROM hardware or software problem.
Solution: Replace inverter.

16

Aux output KO
Cause: Problem with electromechanical brake.
Solution: This is generally a temporary problem due to certain working condi‑
tions. If problem persists, replace inverter.

17

Logic failure #3
Cause: Activated in the event of high inverter current peaks.
Solution: This is generally a temporary problem due to certain working condi‑
tions. If problem persists, replace inverter.

18

Logic Failure #2
Cause: Internal fault in the inverter.
Solution: Replace inverter.

19

Logic failure #1
Cause: Sudden voltage surge or voltage drop.
Solution: This is a temporary problem due to certain working conditions. If pro‑
blem persists, replace inverter.

30

VMN low
Cause: Inverter power supply voltage is lower than battery voltage, or alternati‑
vely incorrect connection to positive battery pole.
Solution: Check connection to positive battery pole. If problem persists, replace
inverter.

31

VMN High
Cause: One motor phase not connected correctly or faulty.
Solution: Check motor phases. If problem persists, replace inverter.

Advertising