SECTION 6 - JLG CONTROL SYSTEM

3121607

– JLG Lift –

6-3

Connect JLG Control System Analyzer

1.

Connect four pin end of cable supplied with hand-held
or wireless analyzer to controller module on platform
box or at controller module inside ground control box.
Connect other end of cable to analyzer.

NOTE: Cable has a keyed four pin connector at each end. It cannot

be connected backwards.

Figure 6-3. Analyzer Platform Connector

Figure 6-4. Analyzer Ground Control Box Connector

NOTE: Follow instructions provided with Wireless Analyzer (WAN-

ALYZER) kit. JLG Analyzer application must be downloaded
and installed to your smartphone or tablet device.

Using Analyzer

1.

Power up Control System by turning lower key to plat-
form or ground position and pulling both emergency
stop buttons out.

Analyzer displays the following with machine power on and
analyzer connected properly:

MENU:

HELP:PRESS ENTER

Move between top level menu items using

RIGHT

and LEFT

arrow keys. To select a dis-

played menu item, press ENTER

. To cancel a selected

menu item press ESC

. Scroll using right and left arrow

keys to select a different menu item.

Top level menus:

HELP

DIAGNOSTICS

SYSTEM TEST

ACCESS LEVEL

PERSONALITIES

MACHINE SETUP

CALIBRATIONS (view only)

Advertising