BASKET ROTATE

ACCELeration

0.1 to 5.0

1.8

DECELeration

0.1 to 3.0

0.7

MlNimum LEFT speed

0 to 65%

46

MAXimum LEFT speed

0 to 100%

50

MINimum RIGHT speed

0 to 65%

46

MAXimum RIGHT speed

0 to 100%

50

Engine RPM

800 to 2900

1500

JIB LIFT

ACCELeration

0.1 to 5.0

5.0

DECELeration

0.1 to 3.0

1.0

MINimum UP speed

0 to 65%

46

MAXimum UP speed

0 to 100%

52

MINimum DOWN speed

0 to 65%

45

MAXimum DOWN speed

0 to 100%

52

Engine RPM

800 to 2900

1800

STEER

MAXimum speed

0 to 100%

100

Engine RPM

800 to 2900

1800

GROUND MODE

Tower LIFT UP speed

0 to 100%

N/A

Tower LIFT DOWN speed

0 to 100%

N/A

Upper LIFT UP

0 to 100%

60

Upper LIFT DOWN

0 to 100%

60

SWING speed

0 to 100%

60

Upper TELEscope speed

0 to 100%

70

Tower TELEscope speed

0 to 100%

N/A

BASKET ROTATE speed

0 to 100%

50

BASKET LEVEL speed

0 to 100%

50

JIB LIFT speed

0 to 100%

50

NOTE:

Personality settings can be adjusted anywhere within the adjustment range for optimum machine performance.

4150365B

Table 6-2. Personality Ranges/Defaults

FUNCTION

PERSONALITY

RANGE

DEFAULTS - 600S