JLG 600SC_660SJC Service Manual User Manual

Page 227

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121607

– JLG Lift –

6-33

DISPLAY UNITS:
22*

0
1

IMPERIAL: DEG F, PSI, LBS
METRIC: DEG C, KPA, KGS.

0

* Certain market selections will alter default setting.

DRIVE CONTROL:
24

0
1
2

NORMAL: Drive coils are energized from the Ground Module.
PROPULSION: Drive coils are energized from the Propulsion Module.
ENHANCED: Drive coils are energized from the Ground Module and the
ground side of the drive coils are brought back to current feedback returns.

2

BOOM CONTROL:
26

0

1

NORMAL: Boom control coils are energized from the Ground Module.

ENHANCED: Boom control coils are energized from the Ground Module and
the ground side of the drive coils are brought back to current feedback
returns.

0

FUNCTION SPEED
KNOB:
27

0
1

YES: Machine is equipped with Function Speed Knob.
NO: Machine is equipped with Operation Speed Knob.

0

CLEARSKY:
28

0
1

NO: ClearSky (Telematics )system option is disabled.
YES: ClearSky (Telematics) system is enabled

0

CRIBBING OPTION:
29

0
1

NO: Cribbing Option is disabled.
YES: Cribbing Option is enabled.

0

FUEL TANK SIZE:
30

0
1

31 Gallon tank.
52 Gallon tank.

0

ALARM/HORN:
31

0
1

SEPERATE: Separate alarm and horn.
COMBINED: combination alarm/horn.

0

ALERT BEACON
32

0
1

OFF FOR CREEP: Alert beacon will not flash in Creep.
20 FPS FOR CREEP: Alert beacon will flash at 20 FPS while in Creep.

0

4150364 G

Table 6-5. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default

Number

Advertising