SECTION 7 - BASIC ELECTRICAL INFORMATION & SCHEMATICS

3121607

– JLG Lift –

7-5

AMP Mate-N-Lok

Follow manufacturer installation instructions.

Figure 7-9. AMP Mate-N-Lok Connector

DIN Connectors

This connector is typically used on hydraulic valves. Follow
manufacturer installation instructions.

Figure 7-10. DIN Connector

Exclusions

Some connectors do not require or may be permanently dam-
aged by application of dielectric grease. Dielectric grease may
not be required in properly sealed enclosures.

DO NOT USE DIELECTRIC GREASE ON BRAD HARRISON/PHOENIX CONTACT
M12 OR AMP JUNIOR TIMER CONNECTORS.

LOW-FORCE CONTACTS CANNOT

DISPLACE DIELECTRIC GREASE AND CREATE ELECTRICAL CONTACT.

BRAD HARRISON/PHOENIX CONTACT M12

This connector uses gold contact material to resist corrosion
and an O-ring seal for moisture integrity. Low-force contacts
cannot displace dielectric grease to achieve electrical contact.
Once contaminated, replacement of female contacts is
required. The JLG Load Sensing System and 1250AJP Rotary
Angle Sensors are examples of components with the M12 con-
nector system.

Figure 7-11. Brad Harrison/Phoenix Connectors

AMP JUNIOR TIMER

This type of connector uses back-seals to keep out moisture.
Low-force contacts cannot displace dielectric grease and cre-
ate electrical contact. Use solvents (i.e. contact cleaner or min-
eral spirits) to remove dielectric grease. The Deutz EMR2
engine control module uses this connector.

Figure 7-12. AMP Junior Timer