Machine configuration programming information -30 – JLG 600SC_660SJC Service Manual User Manual

Page 224

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-30

– JLG Lift –

3121607

Table 6-5. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default

Number

NOTE: Machine configuration must be completed before any personality settings can be changed. Changing personality set-

tings first and then changing the model number of the machine configuration will cause personality settings to return to
default

MODEL NUMBER:
1

6

600SC

1

MARKET:
2

0
1
2
3
4
5

ANSI USA
ANSI EXPORT
CSA
CE
AUSTRALIA
JAPAN

0

ENGINE:
3

12
16

DEUTZ ECM: Deutz Engine Control Module (Tier 2 and 3)
DEUTZ ECM T4F: Deutz Engine Control Module (Tier 4 Final)

14

GLOW PLUG:
5

0
1
2

NO GLOW PLUGS: No glow plugs installed.
AIR INTAKE: Glow plugs installed in the air intake on the manifold.
IN-CYLINDER: Glow plugs installed in each cylinder.

2

STARTER LOCKOUT:
6

0

1

DISABLED: Automatic pre-glow time determined by ambient air tempera-
ture; engine start can be attempted at any time during pre-glow.

ENABLED: Automatic pre-glow time determined by ambient air tempera-
ture; engine start is NOT permitted until pre-glow is finished.

0

FUEL CUTOUT:
7

0

1

2

RESTART: Engine allowed to be restarted multiple times when very low
fuel level is reached.

ONE RESTART: Engine allowed to be restarted once for 2 minutes when very
low fuel level is reached.

ENGINE STOP: Engine not able to restart when very low fuel level is reached.

0

*This menu item is only visible if non dual fuel engines are selected.

ENGINE SHUT-
DOWN:
8

0

1

DISABLED: No engine shutdown.

ENABLED: Shutdown engine when coolant temperature is greater than
110°C or oil pressure is less than 8 PSI.

1