Clean fuel strainer, 8 spark arrester cleaning instructions, 9 glow plugs – JLG 600SC_660SJC Service Manual User Manual

Page 87: Clean fuel strainer -51, Spark arrester cleaning instructions -51, Glow plugs -51

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3121607

– JLG Lift –

3-51

Clean Fuel Strainer

FUEL IS FLAMMABLE AND CAN CAUSE DEATH OR SERIOUS INJURY. MAKE SURE
NO OPEN FLAMES OR SPARKS ARE IN THE AREA WHEN WORKING ON FUEL
SYSTEM. DO NOT SMOKE WHEN WORKING ON FUEL SYSTEM.

1.

Unscrew hexagonal nut (1).

2.

Remove fuel strainer cover (2).

3.

Clean fuel strainer with diesel fuel and replace as
needed.

4.

Place seal (3) in position.

5.

Install fuel strainer cover (2). Tighten screw (1).

6.

Check for leaks.

3.8

SPARK ARRESTER CLEANING INSTRUCTIONS

1.

Remove cleanout plug in bottom of spark arrester (muf-
fler).

2.

Without causing deformation (or any type of damage to
spark arrester) repeatedly tap on arrester near cleanout
plug. This may be enough to begin spark trap drainage.

3.

An industrial vacuum cleaner can do a complete job at
this point.

a. Or, IN A SAFE AREA, start engine. Alternate between

low idle and high idle for two to three minutes.

b. Or, operate engine as required by application for

two to three minutes.

4.

Install cleanout plug.

3.9

GLOW PLUGS

If glow plug option is enabled in the JLG Control System, glow
plug and indicator lamp will be energized when Power/Emer-
gency Stop switch is pulled on if ambient air temperature is
less than 50° F (10° C) and engine coolant temperature is less
than 140° F (60° C).

This determination occurs one second after the Power/Emer-
gency Stop switch has been pulled on. Lamp and glow plugs
remain energized for period of time specified by setting in the
JLG Control System. Engine start is disabled during this period.

On Deutz engines, glow plugs continue (post glow) after
engine has started three times the machine digit setting.