Help message/fault listing -26 – JLG 600SC_660SJC Service Manual User Manual

Page 220

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-26

– JLG Lift –

3121607

Table 6-4. Help Message/Fault Listing

HELP MESSAGE

FAULT

FAULT REMOVAL

OK

0

0

CLEARS WHEN FAULT IS REMOVED

DRIVING AT CREEP - TILTED

0

0

CLEARS WHEN FAULT IS REMOVED

FSW OPEN

0

0

CLEARS WHEN FAULT IS REMOVED

RUNNING AT CREEP - CREEP SWITCH OPEN

0

0

CLEARS WHEN FAULT IS REMOVED

RUNNING AT CREEP - TILTED AND ABOVE ELEVATION

0

0

CLEARS WHEN FAULT IS REMOVED

RUNNING AT CUTBACK - ABOVE ELEVATION

0

0

CLEARS WHEN FAULT IS REMOVED

TILT SENSOR OUT OF RANGE

0

0

CLEARS WHEN FAULT IS REMOVED

LOAD SENSOR READING UNDER WEIGHT

0

0

CLEARS WHEN FAULT IS REMOVED

FSW FAULTY

2

1

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

KEYSWITCH FAULTY

2

1

CLEARS WHEN FAULT IS REMOVED

DRIVE LOCKED - JOYSTICK MOVED BEFORE FOOTSWITCH

2

2

CLEARS WHEN FAULT IS REMOVED

FSW INTERLOCK TRIPPED

2

2

CLEARS WHEN FAULT IS REMOVED

STEER LOCKED - SELECTED BEFORE FOOTSWITCH

2

2

CLEARS WHEN FAULT IS REMOVED

STEER SWITCHES FAULTY

2

2

CLEARS WHEN FAULT IS REMOVED

D/S JOY. QPROX BAD

2

2

CLEARS WHEN FAULT IS REMOVED

L/S JOY. QPROX BAD

2

3

CLEARS WHEN FAULT IS REMOVED

D/S JOY. OUT OF RANGE LOW

2

2

CLEARS WHEN FAULT IS REMOVED

D/S JOY. OUT OF RANGE HIGH

2

2

CLEARS WHEN FAULT IS REMOVED

L/S JOY. OUT OF RANGE LOW

2

3

CLEARS WHEN FAULT IS REMOVED

L/S JOY. OUT OF RANGE HIGH

2

3

CLEARS WHEN FAULT IS REMOVED

D/S JOY. CENTER TAP BAD

2

2

CLEARS WHEN FAULT IS REMOVED

L/S JOY. CENTER TAP BAD

2

3

CLEARS WHEN FAULT IS REMOVED

WAITING FOR FSW TO BE OPEN

2

2

CLEARS WHEN FAULT IS REMOVED

PUMP POT FAULTY

2

3

CLEARS WHEN FAULT IS REMOVED

PUMP SWITCHES FAULTY - CHECK DIAGNOSTICS/BOOM

2

3

CLEARS WHEN FAULT IS REMOVED

PUMP SWITCHES LOCKED - SELECTED BEFORE FOOTSWITCH

2

3

CLEARS WHEN FAULT IS REMOVED

PUMP SWITCHES LOCKED - SELECTED BEFORE START SWITCH

2

3

CLEARS WHEN FAULT IS REMOVED

FOOTSWITCH SELECTED BEFORE START

2

3

CLEARS WHEN FAULT IS REMOVED

BOOM PREVENTED - DRIVE SELECTED

2

5

CLEARS WHEN FAULT IS REMOVED

DRIVE PREVENTED - ABOVE ELEVATION

2

5

CLEARS WHEN FAULT IS REMOVED

DRIVE PREVENTED - TILTED & ABOVE ELEVATION

2

5

CLEARS WHEN FAULT IS REMOVED

DRIVE PREVENTED - BOOM SELECTED

2

5

CLEARS WHEN FAULT IS REMOVED

FORD ECM POWER SHORT TO GROUND

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

HORN SHORT TO GROUND

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

HORN OPEN CIRCUIT

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

HORN SHORT TO BATTERY

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

AUX POWER SHORT TO GROUND

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

AUX POWER OPEN CIRCUIT

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

AUX POWER SHORT TO BATTERY

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

GLOW PLUG SHORT TO GROUND

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

GLOW PLUG OPEN CIRCUIT

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

GLOW PLUG SHORT TO BATTERY

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

LP LOCK SHORT TO GROUND

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

LP LOCK OPEN CIRCUIT

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

LP LOCK SHORT TO BATTERY

3

3

REQUIRES EMS TO BE RECYCLED TO CLEAR FAULT

Advertising