SECTION 6 - JLG CONTROL SYSTEM

3121607

– JLG Lift –

6-23

LIFT UP DUMP SHORT TO

BATTERY

LIFT DOWN HOLDING SHORT TO
GROUND

LIFT DOWN HOLDING OPEN CIR-
CUIT

LIFT DOWN SHORT TO BATTERY

HOUR METER OPEN CIRCUIT

This fault cannot be detected during normal operation. It may be reported dur-
ing self test.

FORD ECM POWER OPEN

CIRCUIT

This fault cannot be detected during normal operation. It may be reported dur-
ing self test.

FORD ECM POWER SHORT TO
BATTERY

This fault cannot be detected during normal operation. It may be reported dur-
ing self test.

3/4

Flash code 3/4 indicates a driver problem on a platform valve block valve driver.
All driver faults are detected in a similar manner. Open circuit faults are detected
when analog feedback reads too high and the output is commanded off. Short
to ground is detected when analog feedback reads low and the output is com-
manded on. Short to battery is detected when analog feedback reads Vbat and
the output is commanded off. Not reported during 2 second power-up.

6

BASKET UP SHORT TO

BATTERY

BASKET UP SHORT TO GROUND

BASKET UP OPEN CIRCUIT

BASKET UP SHORT TO

BATTERY OR OPEN CIRCUIT

Only occurs on machines with electronic basket leveling

BASKET DOWN SHORT TO BAT-
TERY

BASKET DOWN SHORT TO
GROUND

BASKET DOWN OPEN

CIRCUIT

BASKET DOWN SHORT TO BAT-
TERY OR OPEN CIRCUIT

Only occurs on machines with electronic basket leveling.

BASKET LEFT SHORT TO

BATTERY

BASKER LEFT SHORT TO
GROUND

BASKET LEFT OPEN CIRCUIT

BASKET RIGHT SHORT TO BAT-
TERY

BASKET RIGHT SHORT TO
GROUND

BASKET RIGHT OPEN CIRCUIT

JIB UP SHORT TO BATTERY

JIB UP SHORT TO GROUND

JIB UP OPEN CIRCUIT

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority