Zapi - 1001092456 power module only -10 – JLG 1230ES Service Manual User Manual

Page 128

Advertising
background image

SECTION 7 - JLG CONTROL SYSTEM

7-10

– JLG Lift –

3121222

Table 7-2. Machine Configuration Programming Information (1001115626-B)

(Machines Equipped with ZAPI - 1001092456 Power Module Only)

Configuration

Digit

Setting

Range

Description

Market Default Setting

0

1

2

3

4

5

1

(Model #)

0
1
2
3
4
5

1230ES
1930ES
2030ES
2630ES
2646ES
3246ES

(Set to your applicable ES Model

0 through 5)

2

(Market *)

0
1
2
3
4
5

ANSI USA

ANSI EXPORT

CSA

CE

AUSTRALIA

JAPAN

0 - (ANSI USA)

(Set to your applicable market)

3

(Tilt Cutout)

0
1

NO - Drive and lift up not prevented while tilted (Ground and Platform Mode).
YES - Drive and lift up prevented while tilted (Ground and Platform Mode).

1

1

1

0

1

1

4

(Drive Cutout)

0
1

NO - Drive and lift up not prevented while elevated.
YES - Drive and lift up prevented while elevated.

1

5

(Charger Interlock)

0

1

DRIVE ONLY - Drive motion prevented while vehicle is charging.
DRIVE AND LIFT UP - Drive and lift up motions are prevented while vehicle is charg-
ing. Required for CE.

0

0

0

0

0

0

6

(Ground Alarm)

0

1

2

NOT INSTALLED - Vehicle alarm will function for Arm Guard (if enabled), Overload (if
LSS enabled, and as a horn.
DESCENT - Vehicle alarm will function for Arm Guard (if enabled), Overload (if LSS
enabled, as a horn and during Lift Down motion.
MOTION - Vehicle alarm will function for Arm Guard (if enabled), Overload (if LSS
enabled, as a horn and during Drive and Lift motion.

2

2

2

0

2

2

7

(Load)

0
1

2

NOT INSTALLED - Load Sensing System (LSS) is not fitted to the vehicle.
CUTOUT PLT - Load Sensing System (LSS) is fitted and Platform Controls are pre-
vented in the event of an Overload. Ground Controls remain functional. This is the
default setting for CE machines.
CUTOUT ALL - Load Sensing System (LSS) is fitted. Platform and GRound Controls
are prevented in the event of an overload.

0

1

0

1

0

1

8

(Battery)

0
1

FLOODED - Batteries are conventional lead-acid type.
AGM - Batteries are absorbed glass mat type.

0

9

(Footswitch)

0
1

NO - Vehicle is not fitted with a footswitch
YES - Vehicle is fitted with a footswitch

0

0

0

0

0

1

Advertising