5 power module - p/n-1001092456, 5 power module - p/n-1001092456 -11, Zapi power module location -11 – JLG 1230ES Service Manual User Manual

Page 87: Zapi power module specs -11

Advertising
background image

SECTION 5 - CONTROL COMPONENTS

3121222

– JLG Lift –

5-11

5.5 POWER MODULE - P/N-1001092456

1 2 3 0 E S S C I S S O R S B U I L T S T A R T I N G I N M I D Y E A R 2 0 1 0
REPLACED THE SEVCON POWER MODULE (P/N-1600473) WITH
THE ZAPI POWER MODULE (P/N-1001092456).

The power module is located inside the left side access
door as shown in Figure 5-5., ZAPI Power Module Loca-
tion. U
se the following instructions when replacing the
power module.

1. Turn machine power off and disconnect the batter-

ies.

2. Locate and remove the power module from the

machine.

3. Note the wire terminal locations when removing the

old power module.

4. Disconnect all wire connectors and cables from the

old power module and remove it from the machine.

5. When installing the new power module, be sure that

the terminals are oriented as shown in Figure 5-5.

6. After installing the new power module, begin con-

necting the wire connectors/cables to the module,
refer to Figure 5-2. if necessary.

7. Where noted, torque all terminal bolts to torque

specifications shown on the front of the module.

8. After all connections to the power module are made,

the batteries can be reconnected.

9. Check for normal machine operation.

Figure 5-5. ZAPI Power Module Location

ZAPI POWER MODULE

P/N - 1001092456

Table 5-1. ZAPI Power Module Specs

Operating Voltage ( B+)

14.5 to 40 VDC

Maximum Current Limits:
Armature
Field
Pump

300 A

40 A

180 A

Standby Current

150 mA

Temperature Range:
Operating
Storage
Thermal Limit

-40°C to 75°C

-40°C to 125°C

75°C to 90°C

Switching Frequency

16 kHz

Advertising