1 line contactor open circuit, 2 line contactor short circuit, 5 function prevented – JLG 1230ES Service Manual User Manual

Page 142

Advertising
background image

SECTION 8 - DIAGNOSTIC TROUBLE CODES

8-10

– JLG Lift –

3121222

259

MODEL CHANGED -
HYDRAULICS SUSPENDED -
CYCLE EMS

The model selection has been changed.

• Check ANALYZER -> MACHINE SETUP -> MODEL NUMBER.
• Replace ground board.

2510

DRIVE PREVENTED -
BRAKES NOT RELEASING

While driving on a level surface, armature
current was > 150A for five seconds.
Brakes assumed to not be releasing prop-
erly.

• Ensure vehicle is not stuck on something preventing movement.
• Check / repair drive motor wiring, brakes or mechanical issues.

2511

ELEV ANGLE SENSOR
FAULTY - NOT MOUNTED

The input voltage from the elevation
angle sensor indicates the elevation
angle sensor is not mounted.

• Check that the elevation angle sensor is securely mounted.
• Check that the elevation angle sensor mechanisms are intact.
• Replace elevation angle sensor.

2512

ELEV ANGLE SENSOR NOT
DETECTING CHANGE

The input voltage from the elevation
angle sensor did not change while vehicle
was lifting up.

• Check that the elevation angle sensor is securely mounted.
• Check elevation angle sensor is not jammed or obstructed.
• If there are any other elevation angle sensor, joystick, or lift up

faults, troubleshoot them before continuing.

• Replace elevation angle sensor.

3-1 Line Contactor Open Circuit

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

311

OPEN CIRCUIT LINE CON-
TACTOR

The power modules line contactor did not
close when energized. Drive, steer and lift
up prevented.

• Check contactor main contact wiring to battery (+) terminal and

power controller terminal B+.

• Contactor solenoid resistance should measure about 52 Ohms.
• Check contactor solenoid wiring to power module 12 position

connector terminal 8 and ground board terminal J1-19.

• Check that power module 12 position connector terminal 8 goes

from 24V to near 0V while contactor should be closing. If this
happens replace contactor.

• Replace the line contactor.

312

CONTACTOR DRIVER PER-
MANENTLY OFF

The power modules line contactor drive
circuitry failed to energize when
requested. Drive, steer and lift up pre-
vented.

• Check continuity between contactor connector pin 1 and ground

board socket J1-19.

• Contactor solenoid resistance should measure about 52 Ohms.
• Check continuity between contactor connector pin 2 and power

module connector socket 8.

• Replace power module.

3-2 Line Contactor Short Circuit

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

321

LINE CONTACTOR
MISWIRED ON OR WELDED

Battery voltage was present at the power
module B+ terminal at power up. Drive,
steer and lift up prevented.

• Check wiring of contactor.
• Check resistance between the studs of the contactor while dis-

connected from the machine.

• Check contactor main contact wiring to battery (+) terminal and

power module terminal B+.

• Check continuity between contactor connector pin 1 and ground

board socket J1-19.

• Check continuity between contactor connector pin 2 and power

module 12 position connector terminal 8.

• Measure voltage between power model B+ and B- terminals. If

24V is present, replace line contactor.

• Replace power module.

2-5 Function Prevented

DTC

FAULT MESSAGE

DESCRIPTION

CHECK