SECTION 8 - DIAGNOSTIC TROUBLE CODES

3121222

– JLG Lift –

8-19

996

POWER MODULE FAILURE -
INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s analog to digital converter does not

respond for the power PCB. This is an internal failure.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

997

POWER MODULE FAILURE -
CHECK POWER CIRCUITS
OR MOSFET SHORT CIR-
CUIT

The power module detected an error in
the power wiring for the drive or pump.

• Refer to Drive Motor Electrical Evaluation in Section 3.5.
• Refer to Pump Motor Electrical Evaluation in Section 4.8.
• Refer to Power Module Electrical Evaluation in Section 3.6.

998

EEPROM FAILURE - CHECK
ALL SETTINGS

The control system detected an
EEPROM failure.

• Replace ground board.

999

FUNCTION LOCKED OUT -
POWER MODULE SOFT-
WARE VERSION IMPROPER

The power module software version is not
compatible with the rest of the system.

• Replace power module to clear fault.

9910

FUNCTION LOCKED OUT -
PLATFORM MODULE SOFT-
WARE VERSION IMPROPER

The platform board software version is
not compatible with the rest of the system.

• Reprogram platform board.

9911

FUNCTION LOCKED OUT -
LSS MODULE SOFTWARE
VERSION IMPROPER

The load sensing system module soft-
ware version is not compatible with the
rest of the system.

• Replace LSS module to clear fault.

9912

POWER MODULE FAILURE -
SYSTEM MONITOR

The ground board detected armature,
field, or pump current while function was
not commanded.

• Refer to Drive Motor Electrical Evaluation in Section 3.5.
• Refer to Pump Motor Electrical Evaluation in Section 4.8.
• Refer to Power Module Electrical Evaluation in Section 3.6.

9924

FUNCTIONS LOCKED OUT -
MACHINE NOT CONFIG-
URED

The control system's memory indicates
that the vehicle has not been configured
(new control system components).

• Use the JLG analyzer to adjust all machine setup and personality

settings, refer to 5.7 Machine Configuration Programming Infor-
mation.

9950 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s armature power circuitry is driven without

PWM command for 100mS.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

9951 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s pump power circuitry is driven without

enable from the interface PCB for 100mS.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

9952 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s pump power circuitry is driven without

PWM command for 100mS.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

9953 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s field power circuitry is driven without

enable from the interface PCB for 100mS.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

9954 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s field power circuitry is driven without

reverse direction from the power PCB for 100mS.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

9955 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s field power circuitry is driven without for-

ward selection from the power PCB for 100mS.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING