SECTION 8 - DIAGNOSTIC TROUBLE CODES

3121222

– JLG Lift –

8-21

99145 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s enable for the power PCB requested a drive

motor or valve activation when not expected.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

99146 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s lift down feedback voltage to the interface

and power PCB’s disagrees.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

99147 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s VMN feedback voltage to the interface and

power PCB’s disagrees.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

99148 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module’s setpoint request from the interface PCB

does not match the input state.

• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

99149 POWER MODULE FAILURE -

INTERNAL ERROR

Drive, Steer, & Lift Prevented

• The System Module encountered an unexpected software issue.
• Cycle machine, if error still exists, replace System Module.
• ZAPI - HEALTH (Status LED) - FLASHING

9-9 Hardware

DTC

FAULT MESSAGE

DESCRIPTION

CHECK