SECTION 8 - DIAGNOSTIC TROUBLE CODES

3121222

– JLG Lift –

8-15

662

CANBUS FAILURE - PLAT-
FORM MODULE

In platform mode, the control system
failed to receive messages from the plat-
form board.

• Turn on machine in ground mode. If DTC 661 is not present check

for 24V between platform box connector terminals D and A. If not
24V, test continuity from platform box connector socket A to
ground board connector socket J1-6 and test continuity from plat-
form box connector socket D to ground board connector socket
J1-7.

• If DTC 661 was present in the previous check, disconnect arm-

stack passthru connector located near the ladder on the left. Turn
on in ground mode. If DTC 661 is not present then there is a prob-
lem in armstack harness. Armstack passthru socket 5 to platform
box terminal E should have continuity. Armstack passthru socket
6 to platform box connector terminal F should have continuity.
Armstack passthru socket 7 to platform box connector terminal G
should have continuity. Armstack passthru socket 5 to armstack
passthru socket 6 resistance should be 120 Ohms +/- 5%. Arm-
stack passthru socket 5 to armstack passthru socket 7 should
measure open circuit. Armstack passthru socket 6 to armstack
passthru socket 7 should measure open circuit.

• Disconnect armstack passthru and ground board J1. Armstack

passthru pin 5 to ground board socket J1-11 should have conti-
nuity. Armstack passthru pin 6 to ground board socket J1-12
should have continuity. Armstack passthru pin 7 to ground board
socket J1-13 should have continuity. Armstack passthru pin 5 to
armstack passthru pin 6 should measure open circuit. Armstack
passthru pin 5 to armstack passthru pin 7 should measure open
circuit. Armstack passthru pin 6 to armstack passthru pin 7
should measure open circuit.

• Disconnect ground board J1 and power module connector.

Ground board socket J1-31 to power module connector socket
10 should have continuity. Ground board socket J1-32 to power
module connector socket 11 should have continuity. Ground
board socket J1-31 to J1-32 should measure open circuit.
Ground board socket J1-31 to J1-33 should measure open cir-
cuit. Ground board socket J1-32 to J1-33 should measure open
circuit.

• Ensure all connections opened above are reconnected. Discon-

nect power module connector. Turn on in platform mode. If DTC
662 is no longer present replace power module.

• If DTC 661 and 662 have been present through above steps

replace ground board.

Continued Next Page

662

(Cont.)

CANBUS FAILURE - PLAT-
FORM MODULE
(Continued)

In platform mode, the control system
failed to receive messages from the plat-
form board.

• Disconnect platform box connector. Open platform box. Discon-

nect platform board connector. Platform box socket E to platform
board J1-3 should have continuity. Platform box socket F to plat-
form board J1-4 should have continuity. Platform box pin E to pin
F should measure open circuit. Platform box pin E to pin G should
measure open circuit. Platform box pin F to pin G should measure
open circuit. If these checks are OK replace platform board.