3 ground controls, 5 function prevented, 3 ground controls -8 2-5 function prevented -8 – JLG 1230ES Service Manual User Manual

Page 140: 2 platform controls

Advertising
background image

SECTION 8 - DIAGNOSTIC TROUBLE CODES

8-8

– JLG Lift –

3121222

2210

TRIGGER CLOSED TOO
LONG WHILE IN NEUTRAL

The trigger switch was closed for more
than five seconds while the joystick was
centered.

• Check if the trigger switch is obstructed or jammed.
• Check the trigger switch signal and wiring to the platform board.

The trigger input (24V) is from platform board terminal J1-1, and
its output (24V when closed) is to platform board terminal J1-8.

• Replace platform board.

2232 FUNCTION PROBLEM -

DRIVE & LIFT BOTH OPEN

The drive and lift inputs are both de-
energized in Platform Mode.

• Check if either function is active, if Yes;
• Repair the wiring or switch to clear the message.
• ZAPI - HEALTH (Status LED) - ON

2-3 Ground Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

231

FUNCTION PROBLEM - LIFT
PERMANENTLY SELECTED

The ground control box lift switch was
closed up or down, during power-up in
ground mode.

• Check if the lift switch is obstructed or jammed.
• Check the lift switch signal and wiring to the ground board. The lift

switch input (24V) is from ground board terminal J2-4, and its
outputs (24V when closed) are to ground board terminals J2-6,
J2-7 (up and down).

• Replace ground board.

232

GROUND LIFT UP / DOWN
ACTIVE TOGETHER

The lift up / down inputs are closed simul-
taneously.

• Check if the lift switch is obstructed or jammed.
• Check the lift switch signal and wiring to the ground board. The lift

switch input (24V) is from ground board terminal J2-4, and its
outputs (24V when closed) are to ground board terminals J2-6
(up), J2-7 (down).

• Replace ground board.

233

FUNCTION PROBLEM -
BRAKE RELEASE PERMA-
NENTLY SELECTED

The manual brake release switch was
closed during power-up.

• Check if the brake release switch is obstructed or jammed.
• Check the brake release switch signal and wiring to the ground

board. The brake release switch input (24V) is from ground board
terminal J1-19, and its output (24V when closed) is to ground
board terminal J1-20.

• If the brakes are released, the machine can be pushed or moved

without drive motor power.

• Replace ground board.

2-5 Function Prevented

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

251

ELEV ANGLE SENSOR
FAULTY - VOLTAGE OUT OF
RANGE

The elevation angle sensor input voltage
is outside the acceptable range of 0.10V -
4.50V.

• Check that the platform elevation sensor is securely mounted and

undamaged.

• Check voltage as displayed on ANALYZER -> DIAGNOSTICS ->

ELEV SENSOR -> ANGLE SNSR. Backprobe ground board J1-15.
If this voltage disagrees with the ANGLE SNSR voltage, replace
the ground board.

• Backprobe the elevation angle sensor connector. Terminal A

should be 4.7V, terminal C should be 0V.

• Check the elevation angle sensor signal and wiring to the ground

board. The elevation angle sensor input is from ground board ter-
minal J1-14 (4.7V), its output (0.1 - 1.2V when stowed) is to
ground board terminal J1-15, and its ground is to ground board
terminal J1-16.

• Replace the ground board.

252

ELEV ANGLE SENSOR HAS
NOT BEEN CALIBRATED

The elevation angle sensor has not been
calibrated.

• Calibrate the elevation angle sensor to clear fault. See Section 5.5.

2-2 Platform Controls

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

Advertising