2 thermal limit (soa), 2 thermal limit (soa) -13, 3 ground output driver – JLG 1230ES Service Manual User Manual

Page 145

Advertising
background image

SECTION 8 - DIAGNOSTIC TROUBLE CODES

3121222

– JLG Lift –

8-13

33297 LEFT BRAKE - SHORT TO

GROUND

Drive and Steer Prevented

• Excessive current flow to the Left Brake Solenoid was detected (J1-

34 NLB).

• ZAPI - HEALTH (Status LED) - ON

33298 STEER LEFT VALVE - SHORT

TO GROUND

Drive, Steer and Lift Up Prevented

• Excessive current flow to the steer left solenoid detected (J2-9

NLV).

• ZAPI - HEALTH (Status LED) - ON

33299 LINE CONTACTOR COIL -

SHORT TO BATTERY

Drive, Lift and Steer Prevented

• Voltage from an external source was detected on the Negative

Main Line Contactor.

• ZAPI - HEALTH (Status LED) - ON

33302 NEGATIVE SUPPLY - SHORT

TO BATTERY

Drive, Lift, and Steer Prevented

• At power-up, the system module detected an external short on

J1-12, J1-17, J1-23, J2-14 or J2-15. Normally these pins are
grounded by the System Module. All functions are prevented to
protect the control system.

• ZAPI - HEALTH (Status LED) - ON

33303 NEGATIVE SUPPLY - SHORT

TO GROUND

Drive, Lift and Steer Prevented

• At power-up, the System Module detected an external short on

J1-12, J1-17, J2-14 or J2-15. Normally these pins are grounded
by the System Module. Since the external ground may compro-
mise integrity, all functions will be prevented.

• ZAPI - HEALTH (Status LED) - ON

33304 RIGHT BRAKE - SHORT TO

GROUND

Drive, and Steer Prevented

• Excessive current flow to the Right Brake solenoid was detected

(J1-33 NRB).

• ZAPI - HEALTH (Status LED) - ON

33305 STEER RIGHT VALVE -

SHORT TO GROUND

Drive, Steer, and Lift Up Prevented

• Excessive current flow to the Steer Right Solenoid was detected

(J2-18 NRV).

• ZAPI - HEALTH (Status LED) - ON

33406 LiFT UP VALVE - SHORT TO

GROUND

Drive, Steer, and Lift Up Prevented

• Excessive current flow to the Lift Up Solenlid was detected at (J2-

2 PDV or J2-16 NDV).

• ZAPI - HEALTH (Status LED) - ON

33407 LIFT DN VALVE - SHORT TO

GROUND

Lift Up and Down Prevented

• Excessive current flow to the Lift Down Solenoid was detected

(J2-16 NDV).

• ZAPI - HEALTH (Status LED) - ON

4-2 Thermal Limit (SOA)

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

421

POWER MODULE TOO HOT -
PLEASE WAIT

The power module has reached thermal
cutout.

• Power down and allow to cool.
• Do not operate in ambients over 140° F (60° C).
• Check for jammed or obstructed drive motors.
• Check for excessively high current consumption in the pump,

ANALYZER -> DIAGNOSTICS -> PUMP -> PUMP CUR over 130
Amps with an empty deck.

• Check for excessively high traction current consumption, ANA-

LYZER -> DIAGNOSTICS -> TRACTION -> ARM CUR over 120
Amps while driving on the level.

422

DRIVING AT CUTBACK -
POWER MODULE CURRENT
LIMIT

The drive portion of the power module
has reached thermal limit.

• Check for jammed or obstructed drive motors.
• Check for excessively high traction current consumption, ANA-

LYZER -> DIAGNOSTICS -> TRACTION -> ARM CUR over 120
Amps while driving on the level.

3-3 Ground Output Driver

DTC

FAULT MESSAGE

DESCRIPTION