Table of programmable parameters 3.2, Ringing and clip er – 2N Wireless 3G router 2N EasyRoute_new design - User manual, 1670 v1.06 User Manual

Page 41

Advertising
background image

Table of Programmable Parameters

3.2

41

Busy tone– frequency

Set the busy tone frequency in [Hz]. You can set up to two frequencies for a dual
tone. The first frequency is obligatory, the other is optional.

Setting options:

100–3,500 Hz

Setting step:

5 Hz

Default setting:

425 Hz for the first tone, the other tone is disabled.

Busy tone – modulation

Set the busy tone modulation, choosing one of the predefined dialtone patterns.

Setting options:

250/250, 330/330, 200/200, 375/375, 500/500

Default setting:

330/330

Continuous tone – frequency

Set the continuous tone frequency in [Hz]. You can set up to two frequencies for a
dual tone. The continuous tone can be used for setting the Disconnect tone
parameter.

Setting options:

100–3,500 Hz

Setting step:

5 Hz

Default setting:

425 Hz for the first tone, the other tone is disabled.

Ringing and CLIP

ER

Frequency

Here set the signal frequency for terminal or PBX ringing in the case of an
incoming GSM call.

Setting options:

10–60 Hz

Setting step:

1 Hz

Default setting:

50 Hz

Modulation

Here set ringing signal modulation, choosing one of the predefined ringing
patterns.

Setting options:

1000/4000, 400/200/400/2000, 1500/3500,2000/4000

Default setting:

1000/4000

CLIP

Set this item to enable sending of a calling GSM line identification. The function
can be enabled if you have a FSK/ETSI receiving device on your telephone line.

Setting options:

Disable
2N

®

EasyRoute restricts CLI towards the telephone line.

FSK during ringing

2N

®

EasyRoute transmits the FSK-based CLI according

to the ETSI EN 300 659 standard during ringing.

Advertising