Table of Programmable Parameters

3.2

43

10 nF

Two-wire Impedance Synthesis

Adjust the telephone line to the FXS interface.

Setting options:

600 Ohm

900 Ohm

600 Ohm + 2.16 µF

900 Ohm + 2.16 µF

270 Ohm + 750 Ohm || 150 nF

220 Ohm + 820 Ohm || 120 nF

220 Ohm + 820 Ohm || 115 nF

370 Ohm + 620 Ohm || 310 nF

Disabled

Pulse Metering Hybrid Adjustment

Set the trans-hybrid feedback for tariff pulse metering. Use this function, for
example, to eliminate penetration of tariff pulses into the wireless network and
potential interference.

Setting options:

+4.08 dB

+2.50 dB

+1.16 dB

0 dB

-1.02 dB

-1.94 dB

-2.77 dB

Off

Audio hybrid adjustment

Set the audio trans-hybrid feedback. Use this function, for example, to suppress
echo more efficiently.

Setting options:

see above

SLIC – FAX Version