2N VoiceBlue Lite - Manual v2.6 User Manual

Page 61

Advertising
background image

2N - VoiceBlue Lite

• If the service mobility extension is not permitted, the table of

CLIP routings is searched. This contains records such as
AutoCLIP routing and DynamicCLIP routing. If in the table
the record AutoCLIP routing is found for the CLIP of the
caller, the caller is directly routed to the branch the number of
which is entered in the field autodial (see chapter 9.5). If the
function AutoCLIP routing is not activated, or if the number of
the caller is not included in the table of AutoCLIP routing, the
handling of the incoming call continues with a search of the
table DynamicCLIP routing. If the number of the caller is
found in this table, the incoming call is directly routed to the
corresponding branch. The function DynamicCLIP routing can
be set in the menu GSM incoming groups (see chapter.9.5).

• If even after this the incoming call is not dealt with, the gate

takes the call and either plays an announcement or dial tone to
the caller. Then VoiceBlue Lite waits for the required number
of numerals necessary for the making of a connection. The
minimum and maximum number of numerals of the DTMF
selection can be set in the menu GSM incoming calls.

• If VoiceBlue Lite does not receive the minimum required

number of numerals, and by the time designated by the
parameter Delay when entering DTMF numerals further
numerals doe not come from GSM, the call is rerouted to the
operator in the same way as when the number of the branch
called by the caller is not known.

• If the function of routing to the operator is not active, the

incoming call is refused.