1 installation procedure, Attention – Atop Technology SE5001 Series User Manual

Page 12

Advertising
background image

User Manual Version 1.6

SE5001 Serial Device Server

Copyright © 2011 Atop Technologies, Inc.

All rights reserved. Designed in Taiwan.

11

Figure 2.2 SE5001 Interfaces (SE5001-S5is)

2.1 Installation Procedure

Step 1: Connect SE5001 to a power source using its 5V

DC Jack or its 9-30V DC Terminal Block.

Note that

the DC Jack is 5V only and should be used with a power adaptor

.

NoteSE5001 provides two power inputs that can be connected simultaneously to different DC
power sources. If any of the power inputs fail, the other power source can act as a backup to
support the power needs automatically. The redundant dual DC power inputs give one extra
assurance of non-stop operation.

Step 2: Connect SE5001 to the Ethernet network. Use a standard straight-through Ethernet cable when

connecting to a hub/switch. To simply the setup, a cross-over Ethernet cable can be used to connect
the serial device server to a PC directly. Please make sure that the PC is in the same network subnet
as SE5001.

Step 3:

Connect SE5001’s serial port to a serial device.

Step 4: Placement options: Mount SE5001 to a wall/panel (Mounting screws included) or Din-Rail rack

(optional Din-Rail-Kit DK-25).

Attention

Disconnect the device from power source completely before installing and wiring
the server.

Do not exceed the maximum allowable current of the power cord and common
wire. Applying the wire over its specification would cause the wire to overheat and
cause serious damage to the connected and neighboring equipment.

The casing could become too hot to touch when operating in harsh environments.
Please handle with care.

Advertising