SE5001 Serial Device Server

Copyright © 2011 Atop Technologies, Inc.

All rights reserved. Designed in Taiwan.

42

Figure 3.35 TCP Server with Multiple Connections Enabled

3.3.18. TCP Server Application: Multi-Point TCP Pair Connections

The difference between Multi-Point TCP Pair Connection and Multi-Point UDP Pair Connection is that the TCP
implementation would also exchange flow controls pins of RS-232. However, the TCP Server is limited to a
maximum of four connections. If there are than four serial devices and does not use flow control pins with RS-232
or RS-485, it is possible to setup pair connection in UDP mode (section

3.3.16

). After multi-connection is enabled in

the WebUI, refer to the following table to setup Pair Connection as in Figure 3.36.

IP Address

Link Mode

Local

Listening

Port

Destination IP

Destination Port

SE5001 Master

10.0.50.100 TCP Server

5000

-

5000

SE5001 Slave 1 10.0.50.200

TCP Client

5000

10.0.50.100

5000

SE5001 Slave 2 10.0.50.201

TCP Client

5000

10.0.50.100

5000

SE5001 Slave 3 10.0.50.202

TCP Client

5000

10.0.50.100

5000

SE5001 Slave 4 10.0.50.203

TCP Client

5000

10.0.50.100

5000