Software setup, 1 configuration by serialmanager, Static ip – Atop Technology SE5001 Series User Manual

Page 14

Advertising
background image

User Manual Version 1.6

SE5001 Serial Device Server

Copyright © 2011 Atop Technologies, Inc.

All rights reserved. Designed in Taiwan.

13

3. Software Setup

SE5001 Ethernet Serial device server is shipped with default settings shown in the following table:

Property

Default Value

IP Address

10.0.50.100

Gateway

10.0.0.254

Subnet Mask

255.255.0.0

User Name

admin

Password

Null(leave it blank)

COM 1

9600,None, 8, 1, No flow control, buffer disabled, packet delimiter timer 2ms

Link 1

Type: TCP Server, Listen port 4660, Filter=0.0.0.0, Virtual COM disabled

SysName of SNMP

name

SysLocation of SNMP location

SysContact of SNMP

contact

3.1 Configuration by SerialManager

3.1.1. Static IP

Use SerialManager in the product CD to configure network parameters of SE5001.


->Execute SerialManager (Figure 3.1)

->In SerialManager, click on the SE5001 that needs to be configured.

->Click on

Configuration”->”Network” or the “Network” button.

->Enter the desired network settings in the

“Network Settings” window (Figure 3.2).

->Click

OK” and SE5001 will restart and apply new settings.