61

Figure 4.17 Port Monitor Trace Panel

The Trace panel provides a detailed, time-stamped, real-time display of all Serial/IP COM ports

operations (Figure 4.17). Click on Enable Trace to start logging Virtual COM communication. Click on
File->Save As and send the log to Atop for analysis If problems arises with Virtual COM.

4.5 Serial/IP Advanced Settings

In the Serial/IP Control Panel, Click on the Advanced button to open Advanced Settings window (Figure 4.18).
Click on Use Default Settings to load the default settings.

Extend Server Connection

Maintains the TCP connection for specified amount of time after COM port is closed

Attempt Server Connection

Terminates pending connection attempts if they do not succeed in the specified time

Synchronize with Server Upon COM Port Open

Required by NT Systems (2000, XP, Vista, 7)

Update Routing Table Upon COM Port Open

Maintains IP route to a server in a different subnet by modifying the IP routing table

Enable Nagle Algorithm

Provides better network efficiency by imposing a minor latency on the data stream while it waits to fill network

packets

Always Limit Data Rate to COM Port Baud Rate

Limits the data rate to the baud rate that is in effect for the virtual COM port