Atop Technology SE5001 Series User Manual

Page 35

Advertising
background image

User Manual Version 1.6

SE5001 Serial Device Server

Copyright © 2011 Atop Technologies, Inc.

All rights reserved. Designed in Taiwan.

34

1 minute.

TCP Keep-Alive: Specify the interval in the

Idle Time Before Sending TCP Alive Packet” to force

SE5001 to send TCP Keep-Alive packets in the set interval to prevent disconnection from the client. Note
that this field has a multiplier of 10, so the default value 4 means to send Keep-Alive packets every 40
seconds.

TCP Inactivity Timeout: Specify the value in

TCP Inactivity Time Before Disconnect” to force SE5001

actively close a TCP connection after some specific inactivity time (no packets). The default value is 0,
which means the SE5001 would never close an established connection.

 Scroll to the bottom of the page and c

lick on “Save Configuration” button to save the changes.

 Go to the Application Configuration section starting from

3.3.11

to apply Virtual COM, Pair Connection,

or Reverse Telnet application if applicable. Otherwise go to the COM Configuration (section

3.3.19

) for

serial settings directly.

Figure 3.27 TCP Client Setup

Advertising