A.3.4 Power Terminal Block Connector

Note: Note: Reverse polarity protection is available in SE5001, so VIN+ and VIN- could be reversed.

A.4 Buzzer/LED Message

A.4.1 Buzzer

“ ^ “: Beep twice

“ = “: Beep off

Message

Description

^===^===^===^===^===^===^... (1sec)

Watchdog problem, return service is required

^^^^^^^^^^^^^^^^^^^^^^^...

Memory problem, return service is required

^==^========^^ (5sec)

Startup OK but AP firmware is disabled

^==^========^^^ (5sec)

Startup OK and AP firmware is enabled

Table 1. Buzzer Message

A.4.2 LAN LED

Message

Description

LED Off

Ethernet Disconnected

LED blinking with Green

Data is transmitting on Ethernet for 100Mbps

LED blinking with Orange

Data is transmitting on Ethernet for 10Mbps

Table 2. LAN LED Message

A.4.3 COM Port LED

Message

Description

LED off

No data is transmitting on COM port

LED on blinking state

Data is transmitting on COM port