Figure 3.33 TCP Server with Reverse Telnet Enabled

 Follow section

3.2.5

to configure SE5001 in TCP Server mode properly.

 Check Enable Pair Connection to enabled Pair Connection application in SE5001.
 Scroll to the bottom of the page and c

lick on “Save Configuration” button to save the changes.

3.3.16. UDP Application: Multi-Point Pair Connection

It is also possible to setup pair connection in UDP mode to have more than one Pair Connection Master or Slave to
communicate to each other. For example, it is possible to setup one Modbus Master and six Modbus Slaves in
UDP (Figure 3.34). Note again that UDP does not guarantee data delivery and only data would be transmitted
over Ethernet; other serial pings are not transmitted.
If RS-232 along with flow control, it is recommended to
use Multi-Point Pair Connection in TCP (section

3.3.18

).

 Note that the Destination IP and Port of the Slaves need to be equal to the Master

’s IP and Port. Local

Listening Port of the Slaves needs to be equal to the Master

’s Destination Port.

Sample Configuration:

IP Address

Link

Mode

Local Listening

Port

Destination IP

Destination Port

SE5001 Master

10.0.50.100

UDP

5000

10.0.50.200~10.0.50.207

5000