1 exception handling, 2 interconnection example, Exception handling – Lenze E94A User Manual
Page 171: Interconnection example, 5function blocks

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
171
5
Function blocks
5.7
L_CamSetContDataPDO - contactor data selection via inputs/PDOs
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.7.1
Exception handling
The following table contains the behaviour of the FB in various special cases:
5.7.2
Interconnection example
[5-15] Interconnection example: Selection of the cam data via PDOs
Special case
Behaviour
Invalid axis data
The bError output is set to TRUE.
Wrong parameterisation of the contactor data
A cam track is output without the wrong cams.
Selection of an invalid cam number
The number of cams is limited to 8, i.e. a cam track with
max. 8 cams is output.
In this case, the bError output is not set to TRUE.
Selection of an invalid cam type
No cam track is output.
The bError output is set to TRUE.