L_TbCount - up/downcounter
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.162
L_TbCount - up/downcounter
This FB is a digital up/downcounter with adjustable limitation.
• Under C04005 you can select if the counter is to be stopped or reset automatically when rea-
ching the limitation.
Inputs
Outputs
Function library:
LenzeToolbox
Runtime software licence:
Motion Control HighLevel
Motion Control TopLevel
Identifier/data type
Information/possible settings
bClockUp
BOOL
Upcounter
FALSETRUE Increase counter by "1".
bClockDown
BOOL
Downcounter
FALSETRUE Reduce counter by "1".
bLoadStartValue
BOOL
Accept starting value
• This input has the highest priority.
TRUE The starting value specified via dnStartValue is loaded into the coun-
ter.
dnStartValue
DINT
Starting value
dnReferenceValue
DINT
Comparison value
Identifier/data type
Value/meaning
dnActualCount
DINT
Current counter content
bCountEQReference
BOOL
Result of the comparison of current counter content and comparison value
TRUE |dnActualCount| ≥ |dnReferenceValue|