L_SdSetPosition - position conversion
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.137.1
Monitoring for counter overflow
This function extension will be available from library V2.02!
If the machine parameters transferred to the FB via the AxisData input are changed afterwards (e.g.
the gearbox factors), this may cause a counter overflow when the position value defined via C04276
is converted from the real unit to the internal unit.
The FB reports an internal counter overflow due to a changed measuring system by the value "-12"
at the dnState status output and activates a corresponding error message:
Error number
Error message in the logbook
Response
61603844
0x3AC0004
L_SdSetPosition:int.pos. overflow (LS_DriveInterface)
Error
61737217
0x3AE0901
L_SdSetPosition:int.pos. overflow (L_SdSetAxisData)
Error