5

Function blocks

5.113

L_PosProfileTable - profile data record management (simple)

424

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.113.1

Profile data table

Profile parameter data is directly entered under the assigned codes.

• Exception: The position assigned to the input dnExtPos_p will be used as target position if pro-

file number 1 is selected.

Conversion of the values into internal values
The profile parameters are always entered in the application unit [unit].

• Since the SB LS_Positioner needs the profile parameters in the internal measuring system, the

FB L_PosProfileTable also stores the values in this measuring system.

• The values must only be reconverted by the FB if the machine parameters transmitted by the

drive interface via the input AxisData have changed.

• In this case the output bBusy is set to TRUE during the conversion and an access to the profile

parameters is not possible.

Profile parameters

Unit

Profile no. 1

Profile no. 2

Profile no. 3

Profile no. 4

Positioning mode

-

C04750/1

C04750/2

C04750/3

C04750/4

Position

Unit

dnExtPos_p

C04751/2

C04751/3

C04751/4

Speed

Unit/t

C04752/1

C04752/2

C04752/3

C04752/4

Acceleration

Unit/t

2

C04753/1

C04753/2

C04753/3

C04753/4

Delay

Unit/t

2

C04754/1

C04754/2

C04754/3

C04754/4

S-ramp time

s

C04755/1

C04755/2

C04755/3

C04755/4

TP sequence profile

-

C04756/1

C04756/2

C04756/3

C04756/4

TP selection

-

C04757/1

C04757/2

C04757/3

C04757/4

Note!

The values to be "taught" are exceptions. They must be selected in the internal measu-

ring system.