Page 424

5
Function blocks
5.113
L_PosProfileTable - profile data record management (simple)
424
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.113.1
Profile data table
Profile parameter data is directly entered under the assigned codes.
• Exception: The position assigned to the input dnExtPos_p will be used as target position if pro-
file number 1 is selected.
Conversion of the values into internal values
The profile parameters are always entered in the application unit [unit].
• Since the SB LS_Positioner needs the profile parameters in the internal measuring system, the
FB L_PosProfileTable also stores the values in this measuring system.
• The values must only be reconverted by the FB if the machine parameters transmitted by the
drive interface via the input AxisData have changed.
• In this case the output bBusy is set to TRUE during the conversion and an access to the profile
parameters is not possible.
Profile parameters
Unit
Profile no. 1
Profile no. 2
Profile no. 3
Profile no. 4
Positioning mode
-
C04750/1
C04750/2
C04750/3
C04750/4
Position
Unit
dnExtPos_p
C04751/2
C04751/3
C04751/4
Speed
Unit/t
C04752/1
C04752/2
C04752/3
C04752/4
Acceleration
Unit/t
2
C04753/1
C04753/2
C04753/3
C04753/4
Delay
Unit/t
2
C04754/1
C04754/2
C04754/3
C04754/4
S-ramp time
s
C04755/1
C04755/2
C04755/3
C04755/4
TP sequence profile
-
C04756/1
C04756/2
C04756/3
C04756/4
TP selection
-
C04757/1
C04757/2
C04757/3
C04757/4
Note!
The values to be "taught" are exceptions. They must be selected in the internal measu-
ring system.