5.98
L_LdSyncOperation - master value connection
372
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
The dnXOffset_p x offset is additively superimposed on the dnXPosIn_p master position and then
projected again on the modulo cycle of the master measuring system. The resulting master position
is output at the dnXActPos_p output.
[5-64] Example: Superimposing an offset on the master position
Tip!
• The dnXOffset_p offset value does not necessarily have to be limited to the modulo value
range of the master cycle. However, it must not exceed the permissible DINT value range
minus the master cycle.
(DINT value range = ±2
31
-1 [increments] ≡ ±32768 [rev])
• The x offset is offset in the L_LdSyncOperation FB in the same way as in the