3 telegram failure detection, 4 signal characteristics, 5function blocks – Lenze E94A User Manual
Page 477

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
477
5
Function blocks
5.127
L_SdInterExtrapolatePosition - signal interpolation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.127.3
Telegram failure detection
An optional telegram failure detection can be activated in C04435, either via toggle input or SyncIn-
put interface (SB LS_SyncInput).
• Telegram failure detection serves to fill in missing process data values.
• The maximum number of accepted telegram failures before interpolation/extrapolation is
stopped can be set in C04434.
5.127.4
Signal characteristics
Extrapolation without telegram failure detection
Selection: Telegram failure detection (C04435) = "0: Deactivated"
[5-85] Input values OK
[5-86] Input values not OK, number of accepted telegram failures = 0