5function blocks – Lenze E94A User Manual
Page 283

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
283
5
Function blocks
5.76
L_DevSMControlEncoder - control word for limiter
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Outputs
14 bSafelyLimitedPosition3
Safely limited position 3 (SLP3)
15 bSafelyLimitedPosition4
Safely limited position 4 (SLP4)
16 bSafeOperatingStop
Safe operating stop (SOS)
23 bSafeStopEmergency
Emergency stop (SSE)
29 bSpecialOperationActive
Special operation is active
Identifier/data type
Information/possible settings
dwControl
DWORD
Bit-coded control signal for the basic function "Limiter".
• Connect this output with the input LIM_dwControl of the SB LS_Limiter.
Bit*
Identifier
Requested/active safety functions with TRUE
* Relating to the output signal dwControl.