4 example: sequence table, 5function blocks – Lenze E94A User Manual
Page 450

5
Function blocks
5.114
L_PosSequencer - sequence control
450
Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.114.4
Example: Sequence table
Parameter
Entry
≡ Action type/action no.
Meaning
C04500/1
5000
-
Execute homing
C04500/2
3001
1
Process action 1 of type "Branching" (3)
C04500/3
9005
5
Process action 5 of type "Counting" (9)
C04500/4
1001
1
Process action 1 of type "Positioning" (1)
C04500/5
7003
3
Process action 3 of type "Waiting" (7)
C04500/6
1002
2
Process action 2 of type "Positioning" (1)
C04500/7
3002
2
Process action 2 of type "Branching" (3)
C04500/8
9005
5
Process action 5 of type "Counting" (9)
C04500/9
3004
4
Process action 4 of type "Branching" (3)
C04500/...
yyxxx
yy
xxx
Process action xxx of type yy
C04500/24
1012
12
Process action 12 of type "Positioning" (1)
C04500/25
0
-
Program end
C04500/26
0
-
Program end
C04500/...
...
...
...
...
C04500/100
0
-
Program end
0
1
1
3
4
2
0
1
1
3
4
2
0
1
End
End
End