5function blocks – Lenze E94A User Manual
Page 351

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05
351
5
Function blocks
5.94
L_LdPosCtrlLin - Master value adjustment via position
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Options for compensating the print mark deviation:
A. Immediate compensation of Δx
TP
• During the compensation speed V
x,comp
delta pulses occur, since the x value is set to its set
position x
TP
when the print mark pulse occurs.
[5-56] Immediate compensation of the print mark deviation Δx
TP
B. Compensation of Δx
TP
via a higher-level compensation profile
• During the compensation speed V
x,comp
, neither delta pulses nor jumps occur since the devi-
ation from the set position of the print mark pulse Δx
TP
is compensated via a profile genera-
tor:
[5-57] Compensation of the print mark deviation Δx
TP
via a higher-level compensation profile