Further objects of an interconnection

22

Lenze · 9400 function library · Reference manual · DMS 6.7 EN · 08/2014 · TD05

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2.4.3

Variable

Variables can be used for a cross-task value exchange and for the use of constant values. The use of

significantly named variables can make the interconnection more clear and easier to maintain.

• If you assign the "safe against mains failure" property to a variable, the value of the variable re-

mains stored even after mains switching.

• A variable can be inserted exactly once with an input (for value assignment) into the intercon-

nection and as often as required with an output (for read access).

[2-5]

Example 1: Variable "SetValue1_s" on the left with input for value assignment and on the right with output for reading ac-

cess

[2-6]

Example 2: Variables (with output) for the constant values 100 %, 0 %, -100 % as well as FALSE and TRUE

Note!

Variables are only assigned at the end of the task cycle! Thus, the variable value will only

be effective in the next task cycle!