Industrial PC | Parameter setting & configuration
Visualisation with »VisiWinNET®«
Configuration of the OPC tunnel
120
L
2.5 EN - 01/2012
13.4.2
External visualisation (remote access)
[13-2] External visualisation using a visualisation IPC (Visu) and a control IPC (controller)
The »VisiWinNET®« application of the external Lenze IPC (Visu) accesses the OPC server of
the control IPC (controller) via the OPC tunnel. In the example, the IP address of the IPC
(controller) is: 192.168.5.99
For configuring OPC tunnel 1, use the oct.xml configuration file in the
\storage\OCT
directory. Enter the corresponding IP address of the control IPC in the
configuration file (as described in the following section).
For configuring OPC tunnel 2, use the oct.xml configuration file. The standard
settings need not be changed.
Note!
For using an external visualisation, the oct.xml configuration file on the
visualisation IPC (Visu) must be adapted accordingly.