Parameter reference

Industrial PC extension modules

200

L

2.5 EN - 01/2012

C1596/12

C1596/13

C1596/14

C1596/15

C1596/16

Parameter | Name:

C1596/12 | ECAT: DC support

Data type: UNSIGNED_8

Index: 22979.12

d

=

0x59C3.0x0C

h

Support of the distributed clocks by the slave:

• Value "0": Distributed clocks are not supported.

• Value "1": Distributed clocks are supported.
Display range

(min. value | unit | max. value)

0

1

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/13 | ECAT: DC support - 64 bits

Data type: UNSIGNED_8

Index: 22979.13

d

=

0x59C3.0x0D

h

Support of the distributed clocks (64 bits) by the slave:

• Value "0": Distributed clocks (64 bits) are not supported.

• Value "1": Distributed clocks (64 bits) are supported.
Display range

(min. value | unit | max. value)

0

1

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/14 | Mailbox support

Data type: UNSIGNED_8

Index: 22979.14

d

=

0x59C3.0x0E

h

Mailbox support by the slave:

• Value "0": Mailbox is not supported.

• Value "1": Mailbox is supported.
Display range

(min. value | unit | max. value)

0

1

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/15 | ECAT: Requested state

Data type: UNSIGNED_32

Index: 22979.15

d

=

0x59C3.0x0F

h

This code displays the state specified by the master. At the same time, the user can request a state here.

Note: This is a debug code. Setting this parameter only sets the state of the currently selected slave. All other nodes

remain in their present states. Changing the state of the slave via this code may cause unstable system states.
Selection list

(Lenze setting printed in bold)

0 Invalid
1 Init
2 Pre-Operational
4 Safe Operational
8 Operational

;

Read access ; Write access … CINH … PLC STOP ; No transfer

Parameter | Name:

C1596/16 | ECAT: Current state

Data type: UNSIGNED_32

Index: 22979.16

d

=

0x59C3.0x10

h

Display of the current state of the slave