Industrial PC | Parameter setting & configuration
IPC backup & restore
Function
The log messages are named from M1 to M7. The following log messages can occur:
Tip!
The online help provides detailed information on
Windows® XP »IPC Backup & Restore«.
A backup covers the following data:
Operating system file and bootloader
Lenze software
System configuration
Data of the software
For the management of the backups created, an »IPC Backup & Restore« version for
Windows® XP is available. This version enables you to store the contents of the USB stick
or CF card on any hard disk. »IPC Backup & Restore« for Windows® XP is described in a
separate document.
The backup, restore and software update processes are identical. For procedure details
please refer to the specified chapters.
Message
Message in the logbook
Remedy
M1
System version is identical to the
selected update packet. No action
necessary.
The version of the Industrial PC is identical to that of the
update.
• Remove the USB stick or
• Change the control file of the USB stick with
»IPC Backup & Restore« under Windows® XP.
M2
Backup finished with <<1>> errors.
During the creation of Backup_orig, errors have occurred.
The update process cannot be continued.
• You can continue using the existing system, or you can try
again.
M3
Migration finished successfully.
Update finished with <<1>> errors.
Insert a backup CF card and restore
old system.
The migration of the databases has been carried out
successfully, but the installation of the update has failed.
Try the following:
• Establish an existing archive on your Compact Flash card.
• Then you can restore Backup_orig from the USB stick to
receive the original state.
M4
Update finished successful
The installation of the SW update has been completely
carried out successfully.
M5
Migration failed. Rollback finished
successful. The system was not
changed. Try Update again.
The migration of the databases has failed. The attempt to
effect a change was carried out in the temporary directory,
so that the Industrial PC was not changed.
• Repeat the update process.
M6
Migration failed. Restore was
successful. The system was not
changed. Try Update again.
The migration of the databases has failed. Afterwards
Backup_orig was restored successfully. Therefore the
original system is available again.
• Repeat the update process.
M7
Migration failed
Restore finished with <<1>> errors.
Insert a backup CF card and restore
old system.
The migration of the databases has failed. Backup_orig could
not be restored either.
Try the following:
• Establish an existing archive on your Compact Flash card.
• Then you can restore Backup_orig from the USB stick to
receive the original state.