2.5 EN - 01/2012

L

63

Industrial PC | Parameter setting & configuration

Programming with the »PLC Designer«

Accessing IPC parameters from the PLC

8.3.2

The LLS_AddLog function block - Generate logbook entry

This function renders it possible to make an entry in the logbook of the Industrial PC.

The function supplies a return value TRUE if the entry was carried out.

Inputs

Function library:

PLCLoggingAccess

LLS_AddLog

T_LLS_Severity ⎯ eSeverity

Status ⎯ BOOL

T_LLS_Facility ⎯ eFacility

Valid ⎯ BOOL

STRING(80) ⎯ sLogPayLoad

Error ⎯ BOOL

Identifier/data type

Information/possible settings

eSeverity

T_LLS_Severity

Logging Severity - risk of the error

• LLS_FatalError

• LLS_Error, LLS_Warning

• LLS_Information

The Enum parameter eSeverity (IEC_INT) transferred to Add2Log as severity (BYTE).

eFacility

T_LLS_Facility

Logging Facility: - area from which the error is reported

• LLS_PLC_USER_LOG_SCOPE1

• LLS_PLC_USER_LOG_SCOPE2

• LLS_PLC_USER_LOG_SCOPE3

The Enum parameter eFacility (IEC_INT) is transferred to Add2Log as Facility

(WORD).

sLogPayLoad

STRING(80)

Logbook entry

The Ansi string from "sLogPayLoad" is transferred to Add2Log as 1-byte string

parameter. ("hs", SLOGPAYLOAD)