Industrial pc | parameter setting & configuration – Lenze PC-based Automation Industrial PC User Manual

Page 206

Advertising
background image

Industrial PC | Parameter setting & configuration

Parameter reference

Industrial PC extension modules

206

L

2.5 EN - 01/2012

C1596/33

C1596/35

C1596/36

C1596/37

C1596/38

Parameter | Name:

C1596/33 | ECAT: PDI error counter

Data type: UNSIGNED_8

Index: 22979.33

d

=

0x59C3.0x21

h

Number of internal errors of the slave, reported by the process data interface.
Display range

(min. value | unit | max. value)

0

255

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/35 | ECAT: Lost link counter - port 0

Data type: UNSIGNED_8

Index: 22979.35

d

=

0x59C3.0x23

h

Number of lost links at port 0.
Display range

(min. value | unit | max. value)

0

255

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/36 | ECAT: Lost link counter - port 1

Data type: UNSIGNED_8

Index: 22979.36

d

=

0x59C3.0x24

h

Number of lost links at port 1.
Display range

(min. value | unit | max. value)

0

255

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/37 | ECAT: Lost link counter - port 2

Data type: UNSIGNED_8

Index: 22979.37

d

=

0x59C3.0x25

h

Number of lost links at port 2.
Display range

(min. value | unit | max. value)

0

255

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/38 | ECAT: Lost link counter - port 3

Data type: UNSIGNED_8

Index: 22979.38

d

=

0x59C3.0x26

h

Number of lost links at port 3.
Display range

(min. value | unit | max. value)

0

255

;

Read access … Write access … CINH … PLC STOP … No transfer