Industrial PC | Parameter setting & configuration
Remote maintenance and diagnostics
Remote Access Service (RAS) connection
12.1.1
RAS client configuration
For being able to establish a RAS connection between the Engineering PC and the IPC RAS
server, you have to establish a remote maintenance connection on the client PC. The
following settings illustrate how to establish an automatic dial-up connection on the
Engineering PC under Windows® XP.
Start the Assistant for new connections on the client computer:
StartSettingsNetwork connections
Start the Wizard for new connections and follow the instructions on the screen.
After the connection has been established successfully you establish a RAS connection
to the Industrial PC using the »WebConfig« or the »Engineer«:
– Enter the IP address of the RAS server in the connection dialog.
– The IP address is generated dynamically by the RAS server.
RAS settings with the web-based parameterisation
RAS settings in the »Engineer«
Note!
In order to be able to establish a RAS connection, a RAS authorisation on the IPC
has to be assigned to the corresponding
Windows® CE user. The authorisation can be allocated via »Engineer« or via
web-based parameterisation.