CLIP-LOC
Cleat
#10-12 x 1" PHW (1'-0" o.c.)
Eave
Double Bead Tape Sealant
Clip-Loc Inside Closure
#9-15 x 1
1
/
2
" Woodscrew XL (6)
Per Panel (see below)
Clip-Loc Panel
Clip-Loc Clip
E
AVE
O
VER
D
ECKING
INSTALLATION NOTES
All eave flashings must be installed prior to panel installation.
1. Position and install Cleat to wall with appropriate fastener, 1'-0" o.c. Make sure Cleat allows for proper Eave attachment.
2. Install Eave flashing by sliding open hem onto Cleat and resting the Eave flashing back against substrate. To hold Eave flashing
in place fasten to substrate with #10-12 x 1" Pancake Head Woodscrew 4'-0" o.c.
3. Apply a row of Double Bead Tape Sealant across Eave flashing approximately 2" from face of Eave flashing.
4. Properly align and install Clip-Loc Inside Closures to accommodate Clip-Loc panel rib alignment. Closures must be lined up
with panel ribs for proper seal. Do not apply tape sealant on top of closure.
5. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead
of tube sealant between the flashings and securing with pop rivets 2
1
/
2
" o.c.
6. Once panels have been installed, (see pages 21-22), fasten through panel, closure, and sealant into substructure with 6 fasteners
per panel. Fasteners must penetrate closure and sealant to eliminate closure movement.
Moisture Barrier (by others)
CAUTION
Additional screws
may be required for
high snow loading
and steep slopes.
0"-1
1
/
2
"
1:12 Slope
Minimum
Clip-Loc Fastening Pattern
#9-15 x 1
1
/
2
" Woodscrew