Clip-loc – Metal Sales Clip-Loc Installation User Manual
Page 54
![background image](/manuals/567685/54/background.png)
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 2/03
812.246.1935 (Corporate Offi ce) • www.mtlsales.us.com
53
CLIP-LOC
R
AKE
P
ARAPET
(O
N
M
ODULE
) O
VER
O
PEN
F
RAMING
Clip-Loc Floating Rake Zee and Clip-Loc panels must be installed prior to rakewall installation (see pages 44-45).
1. With Clip-Loc panel properly nested over top of Clip-Loc Floating Rake Zee, apply a row of Double Bead Tape Sealant across
top of panel rib.
2. Install Clip-Loc Rakewall flashing on top of panel rib. Fasten through Clip-Loc Rakewall, sealant, roof panel, and into Clip-
Loc Floating Rake Zee with ¼-14 x
7
/
8
" Stitch XL 1'-0" o.c.
3. Install Counter Flashing, Reglet, or wall panel and fasten to parapet wall with appropriate fastener 1'-0" o.c. If Counter Flashing
or Reglet is used seal to parapet wall with tube sealant. Do Not Fasten Clip-Loc Rakewall to wall.
4. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead
of tube sealant between the flashings and securing with pop rivets 2
1
/
2
" o.c.
Double Bead Tape Sealant
#
1
/
4
-14 x
7
/
8
" Stitch XL (1'-0" o.c.)
Clip-Loc Panel
Floating Rake Zee
Clip-Loc Rakewall
#12-14 x 1
1
/
4
" Shoulder Tech (1'-0" o.c.)
1:12 Slope
Minimum
INSTALLATION NOTES