Clip-loc – Metal Sales Clip-Loc Installation User Manual

Page 60

Advertising
background image

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 2/03

812.246.1935 (Corporate Offi ce) • www.mtlsales.us.com

59

CLIP-LOC

V

ENTED

R

IDGE

O

VER

O

PEN

F

RAMING

Double Bead Tape Sealant

#

1

/

4

-14 x

7

/

8

" Stitch XL (8" o.c.)

Perforated Vent Drip

Clip-Loc Clip

Clip-Loc Outside Closure

SSR Ridge

Clip-Loc Panel

#

1

/

4

-14 x

7

/

8

" Stitch XL (1'-0" o.c.)

C

L

1. Once panels have been installed, slide Clip-Loc Turn-up Tool over end of panel and bend pan up until flush with top of panel
rib. Turn up all Clip-Loc pans on both sides of ridge (see page 19).
2. Apply a row of Double Bead Tape Sealant across panel, up and over all ribs approximately 2"-4" from panel end on both sides
of

ridge.

3. Install a Clip-Loc Outside Closure over tape sealant. Before continuing, make sure closure placement will accommodate 13"
Step Ridge Cover and Perforated Vent Drip. Set closure in tape sealant.
4. Once all closures have been installed, place a row of Double Bead Tape Sealant across the top of closures on both sides of ridge.
5. Install Perforated Vent Drip and properly align for 13" Step Ridge Cover. Once Perforated Vent Drip has been properly aligned,
secure Perforated Vent Drip to panel ribs with ¼-14 x

7

/

8

" Stitch XL 8" o.c. at every rib.

6. Apply a row of Double Bead Tape Sealant across end of Perforated Vent Drip.
7. Install ridge flashing and secure to Perforated Vent Drip with a ¼-14 x

7

/

8

" Stitch XL at 1'-0" o.c. avoiding panel ribs.

8. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead
of tube sealant between the flashings and securing with pop rivets 2

1

/

2

" o.c.

Double Bead Tape Sealant

2"

1:12 Slope
Minimum

INSTALLATION NOTES

Clip-Loc panel must be anchored to solid deck behind outside closure at all ridge, hip, endwall, and peak

conditions to fi x the panel when using this fl oating eave detail.